How does terminal connection wire optimize low-voltage, low-current signal transmission?

Publish Time: 2025-09-16
Low-voltage, low-current signal transmission is ubiquitous in modern electronic and automation systems. A large number of signals are transmitted in the form of millivolt voltages or milliamperes. These signals are characterized by low energy, susceptibility to interference, and sensitivity to contact resistance, placing extremely high demands on the reliability of the connecting components. Against this backdrop, terminal connection wire, as the "nerve connection" of the electrical system, plays a crucial role in low-voltage, low-current signal transmission through a series of material, structural, and process optimizations, ensuring signal integrity, stability, and distortion-free.

1. Low Contact Resistance: Ensuring Signal Integrity

One of the biggest challenges with low-voltage, low-current signals is the impact of contact resistance. Even a tiny resistance can cause a significant voltage drop, resulting in signal attenuation or misinterpretation. For example, in a thermocouple temperature measurement system, an error of 0.1mV can correspond to a temperature deviation of several degrees Celsius. To this end, high-quality terminal connection wire uses high-conductivity copper as its conductor, and the terminal surface is plated with gold, silver, or tin. The gold plating offers extremely low contact resistance and excellent oxidation resistance, ensuring long-term stable conduction, making it particularly suitable for precision signal connections. Furthermore, cold crimping or ultrasonic welding is used between the terminal and the wire to ensure close metal-to-metal contact, preventing resistance fluctuations caused by loose connections or looseness.

2. Anti-interference Design: Improving Signal Noise Resistance

Low-current signals are highly susceptible to electromagnetic interference (EMI) and crosstalk. Ordinary wires can act like antennas, picking up ambient noise and causing signal distortion. To address this, terminal connection wires used for signal transmission often utilize shielding structures, such as copper mesh or aluminum foil shielding, and utilize ground terminals to effectively dissipate interference currents. Furthermore, twisted-pair terminal connection wires can further mitigate external magnetic field interference.

3. Insulation Material Optimization: Preventing Leakage and Crosstalk

Low-current signals place extremely high demands on insulation performance. Poor-quality or moisture-damaged insulation materials can cause tiny currents to leak, impacting system accuracy. To this end, signal terminal connection wires are often made of high-insulation resistance materials, such as polyethylene (PE), polytetrafluoroethylene (PTFE), or silicone rubber. Their volume resistivity can reach over 10⁵ Ω·cm, effectively blocking leakage current paths. Furthermore, the insulation layer's uniform thickness and absence of pinhole defects prevent capacitive coupling or short circuits between adjacent lines. In high-density wiring applications, color-coded insulation can also prevent wiring errors and improve system reliability.

4. Miniaturization and High-Density Connections: Adapting to the Demands of Precision Equipment

Modern electronic equipment is trending towards miniaturization and integration, placing higher demands on the space occupied by connecting cables. Signal terminal connection wires utilize miniature terminals and fine-gauge wires, enabling high-density wiring within limited spaces. Furthermore, the terminal structure is compact and supports pluggable connections, facilitating modular assembly and maintenance. For example, in medical monitors or industrial I/O modules, rows of pre-insulated terminal wires enable rapid signal connection, significantly improving production efficiency.

5. Environmental Adaptability and Long-Term Stability

Low-voltage signal systems are often used in industrial or outdoor equipment subject to long-term operation. Terminal connection wire must exhibit excellent resistance to heat, moisture, and corrosion. For example, silicone-insulated wire maintains flexibility in temperatures ranging from -60°C to 200°C, making it suitable for extreme environments. Tinned copper wire resists oxidation in humid environments. Furthermore, the terminal housing is constructed of flame-retardant material to prevent fires in unusual circumstances.

In low-voltage, low-current signal transmission, terminal connection wire is more than just a simple conductor connection; it also plays a crucial role in ensuring signal integrity, interference immunity, and system reliability. Through low contact resistance materials, shielding design, high insulation performance, and precision manufacturing, it effectively overcomes the various challenges of weak signal transmission.
×